2026 ICD-10-CM Diagnosis Code T82.592SOther mechanical complication of artificial heart, sequela

ICD-10-CM CodesS00–T88T80-T88T82

ICD-10-CM T82.592S
CMSSource: CMS FY 2026 ICD-10-CM dataset · Effective Oct 1, 2025 – Sep 30, 2026

T82.592S is a billable ICD-10-CM diagnosis code for other mechanical complication of artificial heart, sequela. The 7th character S marks it as a sequela code, which reports a problem that remains after the original condition has resolved. It is valid on HIPAA claims for fiscal year 2026 (October 1, 2025 through September 30, 2026) and groups to MS-DRG 922 through 923. The code is exempt from POA reporting. In AHRQ's Clinical Classifications Software (CCSR), this diagnosis falls under Complication, sequela.

Code Identity

ICD-10-CM Code
T82.592S
Billable Status
Yes — Valid for Submission
Code Describes
Other mechanical complication of artificial heart, sequela
Short Description
Other mechanical complication of artificial heart, sequela
Same as the full description in the CMS dataset.
Parent Code
Other mechanical complication of artificial heart

Code Classification

ChapterS00–T88Injury, poisoning and certain other consequences of external causes
SectionT80-T88Complications of surgical and medical care, not elsewhere classified
CategoryT82Complications of cardiac and vascular prosthetic devices, implants and grafts
This CodeT82.592SOther mechanical complication of artificial heart, sequela

Present on Admission (POA)Billing

T82.592S is exempt from POA reporting on inpatient claims to general acute care hospitals. Review other POA exempt codes.

Coding GuidelinesGuidance

The appropriate 7th character is to be added to each code from block Complications of cardiac and vascular prosthetic devices, implants and grafts (T82). Use the following options for the applicable episode of care:

  • A - initial encounter
  • D - subsequent encounter
  • S - sequela

Source: ICD-10-CM Official Guidelines for Coding and Reporting, FY 2026, published by CMS and the National Center for Health Statistics.

Clinical ClassificationClinical

AHRQ’s CCSR groups this code into broader clinical categories.

CCSR INJ076
Complication, sequela
Default principal diagnosis: inpatient Yes · outpatient Yes

Convert T82.592S to ICD-9-CMHistory

The closest ICD-9-CM equivalents under the General Equivalence Mappings.

ICD-9-CM
909.3 Late eff surg/med compl
Approximate The match is approximate rather than exact.

Code HistoryHistory

FY 2016AddedAdded to the ICD-10-CM code setEffective October 1, 2015, the first year of ICD-10-CM.
FY 2017–2025No changes
FY 2026CurrentCurrent code set, no changesEffective October 1, 2025 through September 30, 2026.

Questions About T82.592SOverview

Is T82.592S (Other mechanical complication of artificial heart) a billable code?

Yes. This is a billable ICD-10-CM code, specific enough to report other mechanical complication of artificial heart, sequela on HIPAA-covered claims from October 1, 2025 through September 30, 2026.

What does the 7th character S in T82.592S mean?

The final character S makes this a sequela code: it reports a lingering problem that remains after the other mechanical complication of artificial heart itself has resolved, not the original event.

What MS-DRG does T82.592S group to?

When other mechanical complication of artificial heart, sequela is the principal diagnosis on an inpatient stay, it groups to MS-DRG 922, 923, with relative weights from 1.0177 to 1.7494 depending on complications. Higher weights mean higher Medicare reimbursement.

Is T82.592S exempt from POA reporting?

Yes. CMS lists this code among those exempt from present on admission reporting, so hospitals do not assign a POA indicator for other mechanical complication of artificial heart, sequela on inpatient claims.

What is the ICD-9 equivalent of T82.592S?

Under the General Equivalence Mappings, other mechanical complication of artificial heart, sequela converts to ICD-9-CM 909.3 (late eff surg/med compl). The mapping is approximate, so confirm the match fits the documentation.