XRH23GBInsertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into 2 or more Cervical Vertebral Joints, Percutaneous Approach, New Technology Group 11

ICD-10-PCS XRH23GB
CMS Source: FY 2026 ICD-10-PCS dataset. Effective Oct 1, 2025 – Sep 30, 2026.FacebookXLinkedInPrint

XRH23GB is a billable ICD-10-PCS procedure code for Insertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into 2 or more Cervical Vertebral Joints, Percutaneous Approach, New Technology Group 11. It is valid on HIPAA claims for fiscal year 2026 (October 1, 2025 through September 30, 2026) and groups to 9 MS-DRGs. The root operation Insertion involves putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.

Code Identity

ICD-10-PCS Code
XRH23GB
Billable Status
Yes — Valid for Submission
Code Describes
Insertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into 2 or more Cervical Vertebral Joints, Percutaneous Approach, New Technology Group 11
Parent Code
Short Description
Insert Pedcl MoRe Stblz in 2-6 C Jt, Perc, New Tech 11

PCS Table Breakdown

Each ICD-10-PCS code is built from seven characters, each an axis of the procedure. Hover or tap the icons for the official CMS definitions.

PositionDesignationValueMeaning
1SectionXNew Technology
2Body SystemRJoints
3OperationHInsertion
4BodyPart2Cervical Vertebral Joints, 2 or more
5Approach3Percutaneous
6Device/Substance/TechnologyGMolybdenum Rhenium Alloy Spinal Stabilization Device
7QualifierBNew Technology Group 11

Code History

FY 2026New code, effective October 1, 2025.
Replaces previously assigned code(s):
  • 0RH13CZ — Insertion of Pedcl Stabl Dev into Cerv Jt, Perc Approach

Similar Procedure Codes

Questions About XRH23GB

Is XRH23GB a billable code?

Yes. XRH23GB is a complete seven-character ICD-10-PCS code, specific enough to report Insertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into 2 or more Cervical Vertebral Joints, Percutaneous Approach, New Technology Group 11 on inpatient claims from October 1, 2025 through September 30, 2026.

What do the characters in XRH23GB mean?

XRH23GB breaks down character by character: the 1st character X is the Section (New Technology); the 2nd character R is the Body System (Joints); the 3rd character H is the Operation (Insertion); the 4th character 2 is the BodyPart (Cervical Vertebral Joints, 2 or more); the 5th character 3 is the Approach (Percutaneous); the 6th character G is the Device/Substance/Technology (Molybdenum Rhenium Alloy Spinal Stabilization Device); the 7th character B is the Qualifier (New Technology Group 11).

What MS-DRG does XRH23GB group to?

On an inpatient stay, Insertion of Molybdenum Rhenium Alloy Spinal Stabilization Device into 2 or more Cervical Vertebral Joints, Percutaneous Approach, New Technology Group 11 maps to MS-DRGs 028, 029, 030, 907, 908, 909, 957, 958, 959, with relative weights from 1.3127 to 7.6199. The MS-DRG sets the fixed Medicare payment for the stay.