XRGA4R7Fusion of Thoracolumbar Vertebral Joint using Custom-Made Anatomically Designed Interbody Fusion Device, Percutaneous Endoscopic Approach, New Technology Group 7
- Billable / Specific Code
XRGA4R7 is a billable ICD-10-PCS procedure code for Fusion of Thoracolumbar Vertebral Joint using Custom-Made Anatomically Designed Interbody Fusion Device, Percutaneous Endoscopic Approach, New Technology Group 7. It is valid on HIPAA claims for fiscal year 2026 (October 1, 2025 through September 30, 2026) and groups to 19 MS-DRGs. The root operation Fusion involves joining together portions of an articular body part rendering the articular body part immobile.
Code Identity
PCS Table Breakdown
Each ICD-10-PCS code is built from seven characters, each an axis of the procedure. Hover or tap the icons for the official CMS definitions.
| Position | Designation | Value | Meaning |
|---|---|---|---|
| 1 | Section | X | New Technology |
| 2 | Body System | R | Joints |
| 3 | Operation | G | Fusion |
| 4 | BodyPart | A | Thoracolumbar Vertebral Joint |
| 5 | Approach | 4 | Percutaneous Endoscopic |
| 6 | Device/Substance/Technology | R | Interbody Fusion Device, Custom-Made Anatomically Designed |
| 7 | Qualifier | 7 | New Technology Group 7 |
Code History
Similar Procedure Codes
Questions About XRGA4R7
Is XRGA4R7 a billable code?
Yes. XRGA4R7 is a complete seven-character ICD-10-PCS code, specific enough to report Fusion of Thoracolumbar Vertebral Joint using Custom-Made Anatomically Designed Interbody Fusion Device, Percutaneous Endoscopic Approach, New Technology Group 7 on inpatient claims from October 1, 2025 through September 30, 2026.
What do the characters in XRGA4R7 mean?
XRGA4R7 breaks down character by character: the 1st character X is the Section (New Technology); the 2nd character R is the Body System (Joints); the 3rd character G is the Operation (Fusion); the 4th character A is the BodyPart (Thoracolumbar Vertebral Joint); the 5th character 4 is the Approach (Percutaneous Endoscopic); the 6th character R is the Device/Substance/Technology (Interbody Fusion Device, Custom-Made Anatomically Designed); the 7th character 7 is the Qualifier (New Technology Group 7).
What MS-DRG does XRGA4R7 group to?
On an inpatient stay, Fusion of Thoracolumbar Vertebral Joint using Custom-Made Anatomically Designed Interbody Fusion Device, Percutaneous Endoscopic Approach, New Technology Group 7 maps to MS-DRGs 028, 029, 030, 426, 427, 428, 447, 448, 450, 451, 456, 457, 458, 907, 908, 909, 957, 958, 959, with relative weights from 1.3127 to 11.0212. The MS-DRG sets the fixed Medicare payment for the stay.
