X2H30R9Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9

  • Billable / Specific Code
ICD-10-PCS X2H30R9
CMS Source: FY 2027 ICD-10-PCS dataset. Effective Oct 1, 2026 – Sep 30, 2027.FacebookXLinkedInPrint

X2H30R9 is a billable ICD-10-PCS procedure code for Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9. It is valid on HIPAA claims for fiscal year 2027 (October 1, 2026 through September 30, 2027) and groups to 15 MS-DRGs. The root operation Insertion involves putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part. In AHRQ's Clinical Classifications Software (CCSR), this procedure falls under Cardiovascular device procedures, NEC.

Code Identity

ICD-10-PCS Code
X2H30R9
Billable Status
Yes — Valid for Submission
Code Describes
Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9
Short Description
Insert Bioprosth Valve in L Fem Vn, Open, New Tech 9
Parent Code

PCS Table Breakdown

Each ICD-10-PCS code is built from seven characters, each an axis of the procedure. Hover or tap the icons for the official CMS definitions.

PositionDesignationValueMeaning
1SectionXNew Technology
2Body System2Cardiovascular System
3OperationHInsertion
4BodyPart3Femoral Vein, Left
5Approach0Open
6Device/Substance/TechnologyRIntraluminal Device, Bioprosthetic Valve
7Qualifier9New Technology Group 9

In the ICD-10-PCS Alphabetic Index

These FY 2027 ICD-10-PCS Alphabetic Index entries lead to this code:

Anatomy or device term that leads here
Anatomy or device term that leads here
Anatomy or device term that leads here
Insertion, Intracardiac Pacemaker, Dual-Chamber
Leads to this code's table
Intracardiac Pacemaker, Dual-Chamber, Insertion
Leads to this code's table
Insertion, Intraluminal Device, Bioprosthetic Valve
Leads to this code's table
Intraluminal Device, Bioprosthetic Valve, Insertion
Leads to this code's table
Conduit to Short-term External Heart Assist System, Insertion
Leads to this code's table
Insertion, Conduit to Short-term External Heart Assist System
Leads to this code's table
New Technology, Insertion, Intracardiac Pacemaker, Dual-Chamber
Leads to this code's table
New Technology, Insertion, Intraluminal Device, Bioprosthetic Valve
Leads to this code's table
New Technology, Insertion, Conduit to Short-term External Heart Assist System
Leads to this code's table

To code insertion of the Dual-Chamber intracardiac pacemaker, open the FY 2027 ICD-10-PCS Alphabetic Index at Insertion, then the subterms Intracardiac Pacemaker, Dual-Chamber. The index leads to table X2H, where the approach, Device/Substance/Technology and qualifier values shown in the breakdown above complete the seven-character code X2H30R9.

Browse the full ICD-10-PCS Alphabetic Index →

Clinical Classification (CCSR)

AHRQ groups this procedure code into these clinical categories.

CAR029
Cardiovascular device procedures, NEC
Clinical domain: Cardiovascular Procedures

Code History

Replaces previously assigned code(s):
  • 06HN0DZ — Insertion of Intralum Dev into L Femor Vein, Open Approach

Questions About X2H30R9

Is X2H30R9 a billable code?

Yes. This is a complete seven-character ICD-10-PCS code, specific enough to report Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9 on inpatient claims from October 1, 2026 through September 30, 2027.

What do the characters in X2H30R9 mean?

The code breaks down character by character: the 1st character X is the Section (New Technology); the 2nd character 2 is the Body System (Cardiovascular System); the 3rd character H is the Operation (Insertion); the 4th character 3 is the BodyPart (Femoral Vein, Left); the 5th character 0 is the Approach (Open); the 6th character R is the Device/Substance/Technology (Intraluminal Device, Bioprosthetic Valve); the 7th character 9 is the Qualifier (New Technology Group 9).

What MS-DRG does X2H30R9 group to?

On an inpatient stay, Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9 maps to MS-DRGs 252, 253, 254, 820, 821, 822, 826, 827, 828, 907, 908, 909, 957, 958, 959, with relative weights from 1.1267 to 7.5502. The MS-DRG sets the fixed Medicare payment for the stay.