ICD-10-PCS Procedure Code 0VUQ8JZ

Supplement Bilateral Vas Deferens with Synth Sub, Endo

ICD-10-PCS Procedure Code 0VUQ8JZ

ICD-10-PCS: 0VUQ8JZ
Short Description: Supplement Bilateral Vas Deferens with Synth Sub, Endo
Long Description: Supplement Bilateral Vas Deferens with Synthetic Substitute, Via Natural or Artificial Opening Endoscopic

This is the 2018 version of the ICD-10-PCS procedure code 0VUQ8JZ

Valid for Submission
The code 0VUQ8JZ is a billable procedure code.

Replacement Code Additional informationCallout TooltipReplacement Code
The Centers for Medicare and Medicaid Services (CMS) and the National Center for Health Statistics (NCHS) has published an update to the ICD-10-PCS diagnosis codes which became effective October 1, 2018. This is a new and revised code for the FY 2019 (October 1, 2018-September 30, 2019).

This code replaces the following previously assigned ICD-10-PCS code(s) listed below:
  • 0VUQ4JZ - Supplement Bi Vas Deferens w Synth Sub, Perc Endo


ICD-10-PCS Table

Section 0 - Medical and Surgical
Body System 0V - Male Reproductive System
Operation 0VU - Supplement
Body Part Approach Device Qualifier
Q - Vas Deferens, Bilateral 8 - Via Natural or Artificial Opening Endoscopic J - Synthetic Substitute Z - No Qualifier

ICD-10-PCS Definitions

Operation Supplement
Definition:
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
Explanation:
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes:
Herniorrhaphy using mesh, free nerve graft, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
Body Part Vas Deferens
Vas Deferens, Bilateral
Vas Deferens, Left
Vas Deferens, Right
Includes:
Ductus deferens
Ejaculatory duct
Approach Via Natural or Artificial Opening Endoscopic
Definition:
Entry of instrumentation through a natural or artificial external opening to reach and visualize the site of the procedure
Device Synthetic Substitute
Includes:
AbioCor(R) Total Replacement Heart
AMPLATZER(R) Muscular VSD Occluder
Annuloplasty ring
Bard(R) Composix(R) (E/X)(LP) mesh
Bard(R) Composix(R) Kugel(R) patch
Bard(R) Dulex(tm) mesh
Bard(R) Ventralex(tm) hernia patch
BRYAN(R) Cervical Disc System
Ex-PRESS(tm) mini glaucoma shunt
Flexible Composite Mesh
GORE(R) DUALMESH(R)
Holter valve ventricular shunt
MitraClip valve repair system
Nitinol framed polymer mesh
Open Pivot (mechanical) valve
Open Pivot Aortic Valve Graft (AVG)
Partially absorbable mesh
PHYSIOMESH(tm) Flexible Composite Mesh
Polymethylmethacrylate (PMMA)
Polypropylene mesh
PRESTIGE(R) Cervical Disc
PROCEED(tm) Ventral Patch
Prodisc-C
Prodisc-L
PROLENE Polypropylene Hernia System (PHS)
Rebound HRD(R) (Hernia Repair Device)
SynCardia Total Artificial Heart
Total artificial (replacement) heart
ULTRAPRO Hernia System (UHS)
ULTRAPRO Partially Absorbable Lightweight Mesh
ULTRAPRO Plug
Ventrio(tm) Hernia Patch
Zimmer(R) NexGen(R) LPS Mobile Bearing Knee
Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

Code Edits

The following code edits are applicable to this code 0VUQ8JZ:

Procedures for males only - this code is intended for procedures for males only.

Diagnostic Related Groups

The procedure code 0VUQ8JZ is grouped in the following Diagnostic Related Group(s) (MS-DRG V35.0)

  • 711 - TESTES PROCEDURES WITH CC/MCC
  • 712 - TESTES PROCEDURES WITHOUT CC/MCC
  • 907 - OTHER O.R. PROCEDURES FOR INJURIES WITH MCC
  • 908 - OTHER O.R. PROCEDURES FOR INJURIES WITH CC
  • 909 - OTHER O.R. PROCEDURES FOR INJURIES WITHOUT CC/MCC
  • 957 - OTHER O.R. PROCEDURES FOR MULTIPLE SIGNIFICANT TRAUMA WITH MCC
  • 958 - OTHER O.R. PROCEDURES FOR MULTIPLE SIGNIFICANT TRAUMA WITH CC
  • 959 - OTHER O.R. PROCEDURES FOR MULTIPLE SIGNIFICANT TRAUMA WITHOUT CC/MCC

Convert to ICD-9-PCS

Previous Code
0VUQ87Z
Next Code
0VUQ8KZ