Male Reproductive System (0V) ICD-10-PCS
The 0V body system covers Medical and Surgical procedures on male reproductive system, with 3,356 ICD-10-PCS codes across 21 root operations, 3,314 of them billable in fiscal year 2026. Each root operation defines a distinct procedural objective, and the info icons show the official definition with a preview of the codes inside.
Root Operations in This Body System 21 operations · 3,356 codes
| Chars 1–3 | Root Operation | Codes | Billable |
|---|---|---|---|
| 0V1 | BypassAltering the route of passage of the contents of a tubular body part | 194 | 192 |
| 0V2 | ChangeTaking out or off a device from a body part and putting back an identical or similar device in or on the same body part without cutting or puncturing the skin or a mucous membrane | 26 | 24 |
| 0V5 | DestructionPhysical eradication of all or a portion of a body part by the direct use of energy, force or a destructive agent | 162 | 160 |
| 0V7 | DilationExpanding an orifice or the lumen of a tubular body part | 38 | 36 |
| 0V9 | DrainageTaking or letting out fluids and/or gases from a body part | 410 | 408 |
| 0VB | ExcisionCutting out or off, without replacement, a portion of a body part | 310 | 308 |
| 0VC | ExtirpationTaking or cutting out solid matter from a body part | 138 | 136 |
| 0VH | InsertionPutting in a non-biological appliance that monitors, assists, performs or prevents a physiological function but does not physically take the place of a body part | 140 | 138 |
| 0VJ | InspectionVisually and/or manually exploring a body part | 50 | 48 |
| 0VL | OcclusionCompletely closing an orifice or the lumen of a tubular body part | 146 | 144 |
| 0VM | ReattachmentPutting back in or on all or a portion of a separated body part to its normal location or other suitable location | 38 | 36 |
| 0VN | ReleaseFreeing a body part from an abnormal physical constraint by cutting or by use of force | 156 | 154 |
| 0VP | RemovalTaking out or off a device from a body part | 430 | 428 |
| 0VQ | RepairRestoring, to the extent possible, a body part to its normal anatomic structure and function | 156 | 154 |
| 0VR | ReplacementPutting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part | 8 | 6 |
| 0VS | RepositionMoving to its normal location or other suitable location all or a portion of a body part | 50 | 48 |
| 0VT | ResectionCutting out or off, without replacement, all of a body part | 96 | 94 |
| 0VU | SupplementPutting in or on biological or synthetic material that physically reinforces and/or augments the function of a body part | 326 | 324 |
| 0VW | RevisionCorrecting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device | 458 | 456 |
| 0VX | TransferMoving, without taking out, all or a portion of a body part to another location to takeover the function of all or a portion of a body part | 10 | 8 |
| 0VY | TransplantationPutting in or on all or a portion of a living body part taken from anotherindividual or animal to physically take the place and/or function of all or a portion of a similarbody part | 14 | 12 |
The info icon shows the official root operation definition and previews the codes in that range.
About the 0V Body System
The ICD-10-PCS root operations within the Male Reproductive System (section 0V) cover a variety of procedural changes made to this body system, ranging from altering the route of passage to physically removing or repairing parts. These operations are essential for coding medical and surgical interventions accurately.
For example, the Bypass operation (0V1) involves changing the pathway of contents within a tubular structure. The Insertion (0VH) entails placing a device that assists or monitors function without replacing body parts, while Removal (0VP) refers to taking out such devices. Other procedures include Destruction (0V5) to eradicate tissue using energy or agents, Dilation (0V7) to enlarge a lumen, and Drainage (0V9) to remove fluids or gases. Surgical cutting operations like Excision (0VB) and Resection (0VT) involve partial or complete removal of tissue. Furthermore, operations such as Repair (0VQ) restore normal function, while Transplantation (0VY) replaces tissue from a donor. These diverse codes support detailed documentation of male reproductive interventions.
Questions About This Page
How many codes are in the 0V body system?
The 0V body system contains 3,356 ICD-10-PCS codes in FY 2026, organized into 21 root operations. 3,314 of them are billable on inpatient claims.
What is a root operation?
The root operation is the third character of every ICD-10-PCS code and names the objective of the procedure. Drainage takes fluid out, Excision cuts out a portion of a body part, and Resection removes all of one. Picking the right root operation is the central skill of PCS coding, so each one above carries its official CMS definition.
Related References
Source: CMS FY 2026 ICD-10-PCS order file and code tables, effective October 1, 2025 through September 30, 2026.