2025 ICD-10-CM Procedure Code 0HRV07B
Replacement of Bilateral Breast using Lumbar Artery Perforator Flap, Open Approach
- ICD-10-PCS Code:
- 0HRV07B
- ICD-10-PCS Code for:
- Replacement of Bi Breast using LAP Flap, Open Approach
- Is Billable?
- Yes - Valid for Submission
- Code Navigator:
0HRV07B is a billable procedure code used to specify the performance of replacement of bilateral breast using lumbar artery perforator flap, open approach. The code is valid for the year 2025 for the submission of HIPAA-covered transactions. The procedure code involves putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part. Procedure code explanation: the body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the replacement procedure. a removal procedure is coded for taking out the device used in a previous replacement procedure total hip replacement, bone graft, free skin graft
0HRV07B PCS Table
In an PCS table each code is represented by up seven alphanumeric characters, with each character in the table respresenting different aspects of the procedure. In the table provided below, each row represents an individual character and includes information about the character's position, designation, label, and procedure notes. For this PCS table the procedure code is in the medical and surgical section and is part of the skin and breast body system, classified under replacement operation. The applicable bodypart for this procedure code is breast, bilateral.
Position | Designation | Character | Label | Procedures Notes |
---|---|---|---|---|
1 | Section | 0 | Medical and Surgical | |
2 | Body System | H | Skin and Breast | |
3 | Operation | R | Replacement | Involves: Explanation:
|
4 | BodyPart | V | Breast, Bilateral | Includes:
|
5 | Approach | 0 | Open | Involves: |
6 | Device | 7 | Autologous Tissue Substitute | Includes:
|
7 | Qualifier | B | Lumbar Artery Perforator Flap |
New 2025 ICD-10-PCS Code
0HRV07B is new to ICD-10-PCS code set for the FY 2025, effective October 1, 2022.
Replacement Code
0HRV07B replaces the following previously assigned ICD-10-PCS code(s):
- 0HRV07Z - Replacement of Bi Breast with Autol Sub, Open Approach
- 0HRV07Z - Replacement of Bi Breast with Autol Sub, Open Approach
- 0HRV07Z - Replacement of Bi Breast with Autol Sub, Open Approach
- 0HRV07Z - Replacement of Bi Breast with Autol Sub, Open Approach
- 0HRV07Z - Replacement of Bi Breast with Autol Sub, Open Approach
- 0HRV07Z - Replacement of Bi Breast with Autol Sub, Open Approach
Other ICD-10-PCS Codes Used for Replacement Breast, Bilateral
What is ICD-10-PCS?
The ICD-10 Procedure Coding System (ICD-10-PCS) is a catalog of procedural codes used by medical professionals for hospital inpatient healthcare settings. The Centers for Medicare and Medicaid Services (CMS) maintain the catalog in the U.S. releasing yearly updates. The 2025 ICD-10-PCS codes are to be used for discharges occurring from October 1, 2024 through September 30, 2025.
Each ICD-10-PCS code has a structure of seven alphanumeric characters and contains no decimals. The first character defines the major "section". Depending on the "section" the second through seventh characters mean different things.