0GW Revision - Endocrine System ICD-10-PCS
The 0GW code range contains 36 ICD-10-PCS codes for Revision procedures on the endocrine system. 35 of the codes are billable and valid for inpatient claim submission in fiscal year 2027.
Root Operation Definition
Revision: Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
Codes in the 0GW Range 36 codes · 35 billable
- 0GW Endocrine System, RevisionNon-billable header
- 0GW000Z Revision of Drainage Device in Pituitary Gland, Open Approach
- 0GW030Z Revision of Drainage Device in Pituitary Gland, Percutaneous Approach
- 0GW040Z Revision of Drainage Device in Pituitary Gland, Percutaneous Endoscopic Approach
- 0GW0X0Z Revision of Drainage Device in Pituitary Gland, External Approach
- 0GW100Z Revision of Drainage Device in Pineal Body, Open Approach
- 0GW130Z Revision of Drainage Device in Pineal Body, Percutaneous Approach
- 0GW140Z Revision of Drainage Device in Pineal Body, Percutaneous Endoscopic Approach
- 0GW1X0Z Revision of Drainage Device in Pineal Body, External Approach
- 0GW500Z Revision of Drainage Device in Adrenal Gland, Open Approach
- 0GW530Z Revision of Drainage Device in Adrenal Gland, Percutaneous Approach
- 0GW540Z Revision of Drainage Device in Adrenal Gland, Percutaneous Endoscopic Approach
- 0GW5X0Z Revision of Drainage Device in Adrenal Gland, External Approach
- 0GWK00Z Revision of Drainage Device in Thyroid Gland, Open Approach
- 0GWK30Z Revision of Drainage Device in Thyroid Gland, Percutaneous Approach
- 0GWK40Z Revision of Drainage Device in Thyroid Gland, Percutaneous Endoscopic Approach
- 0GWKX0Z Revision of Drainage Device in Thyroid Gland, External Approach
- 0GWR00Z Revision of Drainage Device in Parathyroid Gland, Open Approach
- 0GWR30Z Revision of Drainage Device in Parathyroid Gland, Percutaneous Approach
- 0GWR40Z Revision of Drainage Device in Parathyroid Gland, Percutaneous Endoscopic Approach
- 0GWRX0Z Revision of Drainage Device in Parathyroid Gland, External Approach
- 0GWS00Z Revision of Drainage Device in Endocrine Gland, Open Approach
- 0GWS02Z Revision of Monitoring Device in Endocrine Gland, Open Approach
- 0GWS03Z Revision of Infusion Device in Endocrine Gland, Open Approach
- 0GWS0YZ Revision of Other Device in Endocrine Gland, Open Approach
- 0GWS30Z Revision of Drainage Device in Endocrine Gland, Percutaneous Approach
- 0GWS32Z Revision of Monitoring Device in Endocrine Gland, Percutaneous Approach
- 0GWS33Z Revision of Infusion Device in Endocrine Gland, Percutaneous Approach
- 0GWS3YZ Revision of Other Device in Endocrine Gland, Percutaneous Approach
- 0GWS40Z Revision of Drainage Device in Endocrine Gland, Percutaneous Endoscopic Approach
- 0GWS42Z Revision of Monitoring Device in Endocrine Gland, Percutaneous Endoscopic Approach
- 0GWS43Z Revision of Infusion Device in Endocrine Gland, Percutaneous Endoscopic Approach
- 0GWS4YZ Revision of Other Device in Endocrine Gland, Percutaneous Endoscopic Approach
- 0GWSX0Z Revision of Drainage Device in Endocrine Gland, External Approach
- 0GWSX2Z Revision of Monitoring Device in Endocrine Gland, External Approach
- 0GWSX3Z Revision of Infusion Device in Endocrine Gland, External Approach
About the 0GW Code Range
These procedures correct part of a malfunctioning device or reposition a displaced device at an endocrine gland. The correction may involve removing or adding device components.
The fourth character identifies the pituitary gland, pineal body, adrenal gland, thyroid gland, parathyroid gland or an endocrine gland. The fifth distinguishes open exposure, entry through a puncture or small incision with or without a scope, and external work. The sixth identifies a drainage, monitoring, infusion or other device. The seventh is always No Qualifier.
Questions About This Page
How many billable codes are in the 0GW range?
Of the 36 codes in this range, 35 are billable and valid for inpatient claim submission from October 1, 2026 through September 30, 2027. Table header codes group them but cannot be reported on claims.
What does the 0GW range classify?
The range classifies Revision procedures, correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device, performed on the endocrine system. Each code adds the body part, approach, device, and qualifier in characters four through seven, and links to its own reference page.
Related References
Source: CMS FY 2027 ICD-10-PCS order file and code tables, effective October 1, 2026 through September 30, 2027.