• Version 2026
  • Billable Code

2026 ICD-10-PCS Procedure Code XX25X0A

Monitoring of Blood Flow, Adhesive Ultrasound Patch Technology, New Technology Group 10

ICD-10-PCS Code:
XX25X0A
ICD-10-PCS Code for:
Monitoring of Blood Flow Adhesive US Patch Tech, New Tech 1
Is Billable?
Yes - Valid for Submission
Code Navigator:

XX25X0A is a billable procedure code used to specify the performance of monitoring of blood flow, adhesive ultrasound patch technology, new technology group 10. The code is valid for the year 2026 for the submission of HIPAA-covered transactions. The procedure code involves determining the level of a physiological or physical function repetitively over a period of time.

XX25X0A PCS Table

In an PCS table each code is represented by up seven alphanumeric characters, with each character in the table respresenting different aspects of the procedure. In the table provided below, each row represents an individual character and includes information about the character's position, designation, label, and procedure notes. For this PCS table the procedure code is in the new technology section and is part of the physiological systems body system, classified under monitoring operation. The applicable bodypart for this procedure code is circulatory.

Position Designation Character Label Procedures Notes
1 Section X New Technology
2 Body System X Physiological Systems
3 Operation 2 Monitoring

Involves:
Determining the level of a physiological or physical function repetitively over a period of time

4 BodyPart 5 Circulatory  
5 Approach X External

Involves:
Procedures performed directly on the skin or mucous membrane and procedures performed indirectly by the application of external force through the skin or mucous membrane

6 Device/Substance/Technology 0 Blood Flow, Adhesive Ultrasound Patch Technology
7 Qualifier A New Technology Group 10

Replacement Code

XX25X0A replaces the following previously assigned ICD-10-PCS code(s):

  • 4A13X51 - Monitoring of Arterial Flow, Peripheral, External Approach
  • 4A13X51 - Monitoring of Arterial Flow, Peripheral, External Approach
  • 4A13X51 - Monitoring of Arterial Flow, Peripheral, External Approach
  • 4A13X51 - Monitoring of Arterial Flow, Peripheral, External Approach
  • 4A13X51 - Monitoring of Arterial Flow, Peripheral, External Approach
  • 4A13X51 - Monitoring of Arterial Flow, Peripheral, External Approach
  • 4A13X51 - Monitoring of Arterial Flow, Peripheral, External Approach
  • 4A14X51 - Monitoring of Venous Flow, Peripheral, External Approach
  • 4A14X51 - Monitoring of Venous Flow, Peripheral, External Approach
  • 4A14X51 - Monitoring of Venous Flow, Peripheral, External Approach
  • 4A14X51 - Monitoring of Venous Flow, Peripheral, External Approach
  • 4A14X51 - Monitoring of Venous Flow, Peripheral, External Approach
  • 4A14X51 - Monitoring of Venous Flow, Peripheral, External Approach
  • 4A14X51 - Monitoring of Venous Flow, Peripheral, External Approach

Other ICD-10-PCS Codes Used for Monitoring Circulatory

What is ICD-10-PCS?

The ICD-10 Procedure Coding System (ICD-10-PCS) is a catalog of procedural codes used by medical professionals for hospital inpatient healthcare settings. The Centers for Medicare and Medicaid Services (CMS) maintain the catalog in the U.S. releasing yearly updates. The 2026 ICD-10-PCS codes are to be used for discharges occurring from October 1, 2025 through September 30, 2026.

Each ICD-10-PCS code has a structure of seven alphanumeric characters and contains no decimals. The first character defines the major "section". Depending on the "section" the second through seventh characters mean different things.