XNS50GAReposition Left Humeral Shaft with Ring External Fixation Device with Automated Strut Adjustment, Open Approach, New Technology Group 10

  • Billable / Specific Code
ICD-10-PCS XNS50GA
CMS Source: FY 2026 ICD-10-PCS dataset. Effective Oct 1, 2025 – Sep 30, 2026.FacebookXLinkedInPrint

XNS50GA is a billable ICD-10-PCS procedure code for Reposition Left Humeral Shaft with Ring External Fixation Device with Automated Strut Adjustment, Open Approach, New Technology Group 10. It is valid on HIPAA claims for fiscal year 2026 (October 1, 2025 through September 30, 2026) and groups to 9 MS-DRGs. The root operation Reposition involves moving to its normal location, or other suitable location, all or a portion of a body part.

Code Identity

ICD-10-PCS Code
XNS50GA
Billable Status
Yes — Valid for Submission
Code Describes
Reposition Left Humeral Shaft with Ring External Fixation Device with Automated Strut Adjustment, Open Approach, New Technology Group 10
Parent Code
Short Description
Reposition L Hmr Shaf w Rng Fix Auto Ajst, Open, New Tech 1

PCS Table Breakdown

Each ICD-10-PCS code is built from seven characters, each an axis of the procedure. Hover or tap the icons for the official CMS definitions.

PositionDesignationValueMeaning
1SectionXNew Technology
2Body SystemNBones
3OperationSReposition
4BodyPart5Humeral Shaft, Left
5Approach0Open
6Device/Substance/TechnologyGRing External Fixation Device with Automated Strut Adjustment
7QualifierANew Technology Group 10

Code History

Replaces previously assigned code(s):
  • 0PSG0CZ — Reposition L Humeral Shaft with Ring Ext Fix, Open Approach

Similar Procedure Codes

Questions About XNS50GA

Is XNS50GA a billable code?

Yes. XNS50GA is a complete seven-character ICD-10-PCS code, specific enough to report Reposition Left Humeral Shaft with Ring External Fixation Device with Automated Strut Adjustment, Open Approach, New Technology Group 10 on inpatient claims from October 1, 2025 through September 30, 2026.

What do the characters in XNS50GA mean?

XNS50GA breaks down character by character: the 1st character X is the Section (New Technology); the 2nd character N is the Body System (Bones); the 3rd character S is the Operation (Reposition); the 4th character 5 is the BodyPart (Humeral Shaft, Left); the 5th character 0 is the Approach (Open); the 6th character G is the Device/Substance/Technology (Ring External Fixation Device with Automated Strut Adjustment); the 7th character A is the Qualifier (New Technology Group 10).

What MS-DRG does XNS50GA group to?

On an inpatient stay, Reposition Left Humeral Shaft with Ring External Fixation Device with Automated Strut Adjustment, Open Approach, New Technology Group 10 maps to MS-DRGs 492, 493, 494, 907, 908, 909, 957, 958, 959, with relative weights from 1.3127 to 7.6199. The MS-DRG sets the fixed Medicare payment for the stay.