5A02210Assistance with Cardiac Output using Balloon Pump, Continuous

  • Billable / Specific Code
ICD-10-PCS 5A02210
CMS Source: FY 2027 ICD-10-PCS dataset. Effective Oct 1, 2026 – Sep 30, 2027.FacebookXLinkedInPrint

5A02210 is a billable ICD-10-PCS procedure code for Assistance with Cardiac Output using Balloon Pump, Continuous. It is valid on HIPAA claims for fiscal year 2027 (October 1, 2026 through September 30, 2027) and groups to MS-DRGs 270, 271, 272. The root operation Assistance involves taking over a portion of a physiological function by extracorporeal means. In AHRQ's Clinical Classifications Software (CCSR), this procedure falls under Cardiac assistance with balloon pump.

Code Identity

ICD-10-PCS Code
5A02210
Billable Status
Yes — Valid for Submission
Code Describes
Assistance with Cardiac Output using Balloon Pump, Continuous
Short Description
Assist with Cardiac Output using Balloon Pump, Continuous
Parent Code

PCS Table Breakdown

Each ICD-10-PCS code is built from seven characters, each an axis of the procedure. Hover or tap the icons for the official CMS definitions.

PositionDesignationValueMeaning
1Section5Extracorporeal or Systemic Assistance and Performance
2Body SystemAPhysiological Systems
3Operation0Assistance
4BodySystem2Cardiac
5Duration2Continuous
6Function1Output
7Qualifier0Balloon Pump

In the ICD-10-PCS Alphabetic Index

These FY 2027 ICD-10-PCS Alphabetic Index entries lead to this code:

Balloon Pump, Continuous, Output
Direct entry for this code
Assistance, Cardiac, Continuous, Output, Balloon Pump
Direct entry for this code
Oxygenation, Supersaturated
Leads to this code's table
Resuscitation, Cardiopulmonary
Leads to this code's table
Leads to this code's table

To code balloon pump of the output continuous, open the FY 2027 ICD-10-PCS Alphabetic Index at Balloon Pump, then the subterms Continuous, Output. The entry lists 5A02210 directly as a complete, billable code.

Browse the full ICD-10-PCS Alphabetic Index →

Clinical Classification (CCSR)

AHRQ groups this procedure code into these clinical categories.

ESA009
Cardiac assistance with balloon pump
Clinical domain: Extracorporeal or Systemic Assistance and Performance

Convert to ICD-9-PCS

Closest ICD-9-PCS equivalents for this code under the General Equivalence Mappings.

37.61
Implant of pulsation balloon
Approximate match.

Code History

Replaced in the FY 2027 code set by:
  • 5A0221E — Assist w Cardiac Output w Blood Flow Modulator, Continuous

Similar Procedure Codes

Questions About 5A02210

Is 5A02210 a billable code?

Yes. This is a complete seven-character ICD-10-PCS code, specific enough to report Assistance with Cardiac Output using Balloon Pump, Continuous on inpatient claims from October 1, 2026 through September 30, 2027.

What is the ICD-10-PCS code for balloon pump of the output continuous?

The FY 2027 ICD-10-PCS Alphabetic Index entry Balloon Pump, Continuous, Output is a direct entry for 5A02210, Assistance with Cardiac Output using Balloon Pump, Continuous, billable on inpatient claims from October 1, 2026 through September 30, 2027.

What do the characters in 5A02210 mean?

The code breaks down character by character: the 1st character 5 is the Section (Extracorporeal or Systemic Assistance and Performance); the 2nd character A is the Body System (Physiological Systems); the 3rd character 0 is the Operation (Assistance); the 4th character 2 is the BodySystem (Cardiac); the 5th character 2 is the Duration (Continuous); the 6th character 1 is the Function (Output); the 7th character 0 is the Qualifier (Balloon Pump).

What MS-DRG does 5A02210 group to?

On an inpatient stay, Assistance with Cardiac Output using Balloon Pump, Continuous maps to MS-DRGs 270, 271, 272, with relative weights from 2.4854 to 5.2665. The MS-DRG sets the fixed Medicare payment for the stay.

What is the ICD-9-PCS equivalent of 5A02210?

Under the General Equivalence Mappings, Assistance with Cardiac Output using Balloon Pump, Continuous crosswalks to ICD-9-PCS 37.61 (Implant of pulsation balloon). The mapping is approximate, so confirm it fits the documentation.