0JWTX2ZRevision of Monitoring Device in Trunk Subcutaneous Tissue and Fascia, External Approach

  • Billable / Specific Code
ICD-10-PCS 0JWTX2Z
CMS Source: FY 2027 ICD-10-PCS dataset. Effective Oct 1, 2026 – Sep 30, 2027.FacebookXLinkedInPrint

0JWTX2Z is a billable ICD-10-PCS procedure code for Revision of Monitoring Device in Trunk Subcutaneous Tissue and Fascia, External Approach. It is valid on HIPAA claims for fiscal year 2027 (October 1, 2026 through September 30, 2027). The root operation Revision involves correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device. In AHRQ's Clinical Classifications Software (CCSR), this procedure falls under Subcutaneous tissue and fascia procedures, NEC.

Code Identity

ICD-10-PCS Code
0JWTX2Z
Billable Status
Yes — Valid for Submission
Code Describes
Revision of Monitoring Device in Trunk Subcutaneous Tissue and Fascia, External Approach
Short Description
Revise of Monitor Dev in Trunk Subcu/Fascia, Extern Approach
Parent Code

PCS Table Breakdown

Each ICD-10-PCS code is built from seven characters, each an axis of the procedure. Hover or tap the icons for the official CMS definitions.

PositionDesignationValueMeaning
1Section0Medical and Surgical
2Body SystemJSubcutaneous Tissue and Fascia
3OperationWRevision
4BodyPartTSubcutaneous Tissue and Fascia, Trunk
5ApproachXExternal
6Device2Monitoring Device
7QualifierZNo Qualifier

In the ICD-10-PCS Alphabetic Index

These FY 2027 ICD-10-PCS Alphabetic Index entries lead to this code:

Anatomy or device term that leads here
Anatomy or device term that leads here
Infusion Device, Pump, Revision of device in, Trunk
Leads to this code's table
Revision of device in, Subcutaneous Tissue and Fascia, Trunk
Leads to this code's table
Vascular Access Device, Tunneled, Revision of device in, Trunk
Leads to this code's table
Vascular Access Device, Totally Implantable, Revision of device in, Trunk
Leads to this code's table
Tissue Expander, Revision of device in, Subcutaneous Tissue and Fascia, Trunk
Leads to this code's table
Contraceptive Device, Revision of device in, Subcutaneous Tissue and Fascia, Trunk
Leads to this code's table
Stimulator Generator, Revision of device in, Subcutaneous Tissue and Fascia, Trunk
Leads to this code's table
Cardiac Rhythm Related Device, Revision of device in, Subcutaneous Tissue and Fascia, Trunk
Leads to this code's table
Subcutaneous Defibrillator Lead, Revision of device in, Subcutaneous Tissue and Fascia, Trunk
Leads to this code's table

Browse the full ICD-10-PCS Alphabetic Index →

Clinical Classification (CCSR)

AHRQ groups this procedure code into these clinical categories.

MST028
Subcutaneous tissue and fascia procedures, NEC
Clinical domain: Musculoskeletal, Subcutaneous Tissue, and Fascia Procedures

Convert to ICD-9-PCS

Closest ICD-9-PCS equivalents for this code under the General Equivalence Mappings.

99.99
Other miscellaneous procedures
Approximate match.

Similar Procedure Codes

Questions About 0JWTX2Z

Is 0JWTX2Z a billable code?

Yes. This is a complete seven-character ICD-10-PCS code, specific enough to report Revision of Monitoring Device in Trunk Subcutaneous Tissue and Fascia, External Approach on inpatient claims from October 1, 2026 through September 30, 2027.

What do the characters in 0JWTX2Z mean?

The code breaks down character by character: the 1st character 0 is the Section (Medical and Surgical); the 2nd character J is the Body System (Subcutaneous Tissue and Fascia); the 3rd character W is the Operation (Revision); the 4th character T is the BodyPart (Subcutaneous Tissue and Fascia, Trunk); the 5th character X is the Approach (External); the 6th character 2 is the Device (Monitoring Device); the 7th character Z is the Qualifier (No Qualifier).

What is the ICD-9-PCS equivalent of 0JWTX2Z?

Under the General Equivalence Mappings, Revision of Monitoring Device in Trunk Subcutaneous Tissue and Fascia, External Approach crosswalks to ICD-9-PCS 99.99 (Other miscellaneous procedures). The mapping is approximate, so confirm it fits the documentation.