2022 ICD-10-PCS Procedure Code 05LP3DZ

Occlusion of Right External Jugular Vein with Intraluminal Device, Percutaneous Approach

Version 2021
Billable Code

Valid for Submission

ICD-10-PCS:05LP3DZ
Short Description:Occlusion R Ext Jugular Vein w Intralum Dev, Perc
Long Description:Occlusion of Right External Jugular Vein with Intraluminal Device, Percutaneous Approach

05LP3DZ is a billable procedure code used to specify the performance of occlusion of right external jugular vein with intraluminal device, percutaneous approach. The code is valid for the year 2022 for the submission of HIPAA-covered transactions.

The procedure code 05LP3DZ is in the medical and surgical section and is part of the upper veins body system, classified under the occlusion operation. The applicable bodypart is external jugular vein, right.

ICD-10-PCS Details

Position Designation Character Label Notes
1 Section 0 Medical and Surgical
2 Body System 5 Upper Veins
3 Operation L Occlusion

Involves:
Completely closing an orifice or the lumen of a tubular body part

Explanation:
The orifice can be a natural orifice or an artificially created orifice

Includes:
  • Fallopian tube ligation, ligation of inferior vena cava
4 BodyPart P External Jugular Vein, Right Includes:
  • Posterior auricular vein
5 Approach 3 Percutaneous

Involves:
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6 Device D Intraluminal Device Includes:
  • Absolute Pro Vascular (OTW) Self-Expanding Stent System
  • Acculink (RX) Carotid Stent System
  • AFX(R) Endovascular AAA System
  • AneuRx(R) AAA Advantage(R)
  • Assurant (Cobalt) stent
  • Carotid WALLSTENT(R) Monorail(R) Endoprosthesis
  • CoAxia NeuroFlo catheter
  • Colonic Z-Stent(R)
  • Complete (SE) stent
  • Cook Zenith AAA Endovascular Graft
  • Driver stent (RX) (OTW)
  • E-Luminexx(tm) (Biliary)(Vascular) Stent
  • Embolization coil(s)
  • Endologix AFX(R) Endovascular AAA System
  • Endurant(R) Endovascular Stent Graft
  • Endurant(R) II AAA stent graft system
  • EXCLUDER(R) AAA Endoprosthesis
  • Express(R) (LD) Premounted Stent System
  • Express(R) Biliary SD Monorail(R) Premounted Stent System
  • Express(R) SD Renal Monorail(R) Premounted Stent System
  • FLAIR(R) Endovascular Stent Graft
  • Formula(tm) Balloon-Expandable Renal Stent System
  • GORE EXCLUDER(R) AAA Endoprosthesis
  • GORE TAG(R) Thoracic Endoprosthesis
  • Herculink (RX) Elite Renal Stent System
  • LifeStent(R) (Flexstar)(XL) Vascular Stent System
  • Medtronic Endurant(R) II AAA stent graft system
  • Micro-Driver stent (RX) (OTW)
  • MULTI-LINK (VISION)(MINI-VISION)(ULTRA) Coronary Stent System
  • Omnilink Elite Vascular Balloon Expandable Stent System
  • Protege(R) RX Carotid Stent System
  • Stent, intraluminal (cardiovascular)(gastrointestinal)(hepatobiliary)(urinary)
  • Talent(R) Converter
  • Talent(R) Occluder
  • Talent(R) Stent Graft (abdominal)(thoracic)
  • Therapeutic occlusion coil(s)
  • Ultraflex(tm) Precision Colonic Stent System
  • Valiant Thoracic Stent Graft
  • WALLSTENT(R) Endoprosthesis
  • Xact Carotid Stent System
  • Zenith AAA Endovascular Graft
  • Zenith Flex(R) AAA Endovascular Graft
  • Zenith TX2(R) TAA Endovascular Graft
  • Zenith(R) Renu(tm) AAA Ancillary Graft
7 Qualifier Z No Qualifier

Explanation:
The value Z is used for the seventh character to indicate that a specific qualifier does not apply to the procedure.

Diagnostic Related Groups - MS-DRG Mapping

The Diagnostic Related Groups (DRGs) are a patient classification scheme which provides a means of relating the type of patients a hospital treats. The procedure code 05LP3DZ is grouped in the following groups for version MS-DRG V38.0 applicable from 10/01/2021 through 09/30/2022.

MS-DRG MS-DRG Title MCD Relative Weight
040PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH MCC013.8648
041PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH CC OR PERIPHERAL NEUROSTIMULATOR012.3497
042PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITHOUT CC/MCC011.9012
143OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITH MCC032.9798
144OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITH CC031.7615
145OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITHOUT CC/MCC031.2246
252OTHER VASCULAR PROCEDURES WITH MCC053.3257
253OTHER VASCULAR PROCEDURES WITH CC052.6536
254OTHER VASCULAR PROCEDURES WITHOUT CC/MCC051.8159
907OTHER O.R. PROCEDURES FOR INJURIES WITH MCC213.9482
908OTHER O.R. PROCEDURES FOR INJURIES WITH CC212.0504
909OTHER O.R. PROCEDURES FOR INJURIES WITHOUT CC/MCC211.371
957OTHER O.R. PROCEDURES FOR MULTIPLE SIGNIFICANT TRAUMA WITH MCC247.4209
958OTHER O.R. PROCEDURES FOR MULTIPLE SIGNIFICANT TRAUMA WITH CC244.2057
959OTHER O.R. PROCEDURES FOR MULTIPLE SIGNIFICANT TRAUMA WITHOUT CC/MCC242.7361

The relative weight of a diagnostic related group determines the reimbursement rate based on the severity of a patient's illness and the associated cost of care during hospitalization.

Convert 05LP3DZ to ICD-9-PCS

The following crosswalk between ICD-10-PCS to ICD-9-PCS is based based on the General Equivalence Mappings (GEMS) information:

What is ICD-10-PCS?

The ICD-10 Procedure Coding System (ICD-10-PCS) is a catalog of procedural codes used by medical professionals for hospital inpatient healthcare settings. The Centers for Medicare and Medicaid Services (CMS) maintain the catalog in the U.S. releasing yearly updates. These 2022 ICD-10-PCS codes are to be used for discharges occurring from October 1, 2021 through September 30, 2022.

Each ICD-10-PCS code has a structure of seven alphanumeric characters and contains no decimals. The first character defines the major "section". Depending on the "section" the second through seventh characters mean different things.