Version 2025
Billable Code

2025 ICD-10-CM Procedure Code 02H30DZ

Insertion of Intraluminal Device into Coronary Artery, Four or More Arteries, Open Approach

ICD-10-PCS Code:
02H30DZ
ICD-10-PCS Code for:
Insertion of Intralum Dev into 4+ Cor Art, Open Approach
Is Billable?
Yes - Valid for Submission
Code Navigator:

02H30DZ is a billable procedure code used to specify the performance of insertion of intraluminal device into coronary artery, four or more arteries, open approach. The code is valid for the year 2025 for the submission of HIPAA-covered transactions. The procedure code involves putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part. insertion of radioactive implant, insertion of central venous catheter

02H30DZ PCS Table

In an PCS table each code is represented by up seven alphanumeric characters, with each character in the table respresenting different aspects of the procedure. In the table provided below, each row represents an individual character and includes information about the character's position, designation, label, and procedure notes. For this PCS table the procedure code is in the medical and surgical section and is part of the heart and great vessels body system, classified under insertion operation. The applicable bodypart for this procedure code is coronary artery, four or more arteries.

Position Designation Character Label Procedures Notes
1 Section 0 Medical and Surgical
2 Body System 2 Heart and Great Vessels
3 Operation H Insertion

Involves:
Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

Includes:
  • Insertion of radioactive implant, insertion of central venous catheter
4 BodyPart 3 Coronary Artery, Four or More Arteries  
5 Approach 0 Open

Involves:
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6 Device D Intraluminal Device Includes:
  • Absolute Pro Vascular (OTW) Self-Expanding Stent System
  • Acculink (RX) Carotid Stent System
  • AFX(R) Endovascular AAA System
  • AneuRx(R) AAA Advantage(R)
  • Assurant (Cobalt) stent
  • Carotid WALLSTENT(R) Monorail(R) Endoprosthesis
  • CoAxia NeuroFlo catheter
  • Colonic Z-Stent(R)
  • Complete (SE) stent
  • Cook Zenith AAA Endovascular Graft
  • Driver stent (RX) (OTW)
  • E-Luminexx(tm) (Biliary)(Vascular) Stent
  • Embolization coil(s)
  • Endologix AFX(R) Endovascular AAA System
  • Endurant(R) Endovascular Stent Graft
  • Endurant(R) II AAA stent graft system
  • EXCLUDER(R) AAA Endoprosthesis
  • Express(R) (LD) Premounted Stent System
  • Express(R) Biliary SD Monorail(R) Premounted Stent System
  • Express(R) SD Renal Monorail(R) Premounted Stent System
  • FLAIR(R) Endovascular Stent Graft
  • Formula(tm) Balloon-Expandable Renal Stent System
  • GORE EXCLUDER(R) AAA Endoprosthesis
  • GORE TAG(R) Thoracic Endoprosthesis
  • Herculink (RX) Elite Renal Stent System
  • Innova(tm) stent
  • LifeStent(R) (Flexstar)(XL) Vascular Stent System
  • Medtronic Endurant(R) II AAA stent graft system
  • Micro-Driver stent (RX) (OTW)
  • MULTI-LINK (VISION)(MINI-VISION)(ULTRA) Coronary Stent System
  • Omnilink Elite Vascular Balloon Expandable Stent System
  • Protege(R) RX Carotid Stent System
  • Stent, intraluminal (cardiovascular)(gastrointestinal)(hepatobiliary)(urinary)
  • Talent(R) Converter
  • Talent(R) Occluder
  • Talent(R) Stent Graft (abdominal)(thoracic)
  • Therapeutic occlusion coil(s)
  • Ultraflex(tm) Precision Colonic Stent System
  • Valiant Thoracic Stent Graft
  • WALLSTENT(R) Endoprosthesis
  • Xact Carotid Stent System
  • Zenith AAA Endovascular Graft
  • Zenith Flex(R) AAA Endovascular Graft
  • Zenith TX2(R) TAA Endovascular Graft
  • Zenith(R) Renu(tm) AAA Ancillary Graft
7 Qualifier Z No Qualifier

Explanation:
The value Z is used for the seventh character to indicate that a specific qualifier does not apply to the procedure.

Replacement Code

02H30DZ replaces the following previously assigned ICD-10-PCS code(s):

  • 02HA0YZ - Insertion of Other Device into Heart, Open Approach
  • 02HA0YZ - Insertion of Other Device into Heart, Open Approach
  • 02HA0YZ - Insertion of Other Device into Heart, Open Approach
  • 02HA0YZ - Insertion of Other Device into Heart, Open Approach
  • 02HA0YZ - Insertion of Other Device into Heart, Open Approach
  • 02HA0YZ - Insertion of Other Device into Heart, Open Approach

Clinical Classification

  • Clinical Category is Other coronary artery procedures (excluding CABG and PCI)

  • CCSR Category Code: CAR005
  • Clinical Domain is Cardiovascular Procedures - CAR contains 29 categories that include cardiovascular procedures such as percutaneous coronary intervention (PCI), coronary artery bypass graft (CABG), and aneurysm repair procedures.

Other ICD-10-PCS Codes Used for Insertion Coronary Artery, Four or More Arteries


What is ICD-10-PCS?

The ICD-10 Procedure Coding System (ICD-10-PCS) is a catalog of procedural codes used by medical professionals for hospital inpatient healthcare settings. The Centers for Medicare and Medicaid Services (CMS) maintain the catalog in the U.S. releasing yearly updates. The 2025 ICD-10-PCS codes are to be used for discharges occurring from October 1, 2024 through September 30, 2025.

Each ICD-10-PCS code has a structure of seven alphanumeric characters and contains no decimals. The first character defines the major "section". Depending on the "section" the second through seventh characters mean different things.