• Version 2025
  • Billable Code

2025 ICD-10-CM Procedure Code 02583ZF

Destruction of Conduction Mechanism using Irreversible Electroporation, Percutaneous Approach

ICD-10-PCS Code:
02583ZF
ICD-10-PCS Code for:
Destruction of Conduction Mechanism using IRE, Perc Approac
Is Billable?
Yes - Valid for Submission
Code Navigator:

02583ZF is a billable procedure code used to specify the performance of destruction of conduction mechanism using irreversible electroporation, percutaneous approach. The code is valid for the year 2025 for the submission of HIPAA-covered transactions. The procedure code involves physical eradication of all or a portion of a body part by the direct use of energy, force, or a destructive agent. Procedure code explanation: none of the body part is physically taken out fulguration of rectal polyp, cautery of skin lesion

02583ZF PCS Table

In an PCS table each code is represented by up seven alphanumeric characters, with each character in the table respresenting different aspects of the procedure. In the table provided below, each row represents an individual character and includes information about the character's position, designation, label, and procedure notes. For this PCS table the procedure code is in the medical and surgical section and is part of the heart and great vessels body system, classified under destruction operation. The applicable bodypart for this procedure code is conduction mechanism.

Position Designation Character Label Procedures Notes
1 Section 0 Medical and Surgical
2 Body System 2 Heart and Great Vessels
3 Operation 5 Destruction

Involves:
Physical eradication of all or a portion of a body part by the direct use of energy, force, or a destructive agent

Explanation:
None of the body part is physically taken out

Includes:
  • Fulguration of rectal polyp, cautery of skin lesion
4 BodyPart 8 Conduction Mechanism Includes:
  • Atrioventricular node
  • Bundle of His
  • Bundle of Kent
  • Sinoatrial node
5 Approach 3 Percutaneous

Involves:
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6 Device Z No Device

Explanation:
The value Z is used for the sixth character to indicate that a specific device does not apply to the procedure.

7 Qualifier F Irreversible Electroporation

Replacement Code

02583ZF replaces the following previously assigned ICD-10-PCS code(s):

  • 02583ZZ - Destruction of Conduction Mechanism, Percutaneous Approach
  • 02583ZZ - Destruction of Conduction Mechanism, Percutaneous Approach
  • 02583ZZ - Destruction of Conduction Mechanism, Percutaneous Approach
  • 02583ZZ - Destruction of Conduction Mechanism, Percutaneous Approach
  • 02583ZZ - Destruction of Conduction Mechanism, Percutaneous Approach
  • 02583ZZ - Destruction of Conduction Mechanism, Percutaneous Approach

Other ICD-10-PCS Codes Used for Destruction Conduction Mechanism


What is ICD-10-PCS?

The ICD-10 Procedure Coding System (ICD-10-PCS) is a catalog of procedural codes used by medical professionals for hospital inpatient healthcare settings. The Centers for Medicare and Medicaid Services (CMS) maintain the catalog in the U.S. releasing yearly updates. The 2025 ICD-10-PCS codes are to be used for discharges occurring from October 1, 2024 through September 30, 2025.

Each ICD-10-PCS code has a structure of seven alphanumeric characters and contains no decimals. The first character defines the major "section". Depending on the "section" the second through seventh characters mean different things.