00PV4JZRemoval of Synthetic Substitute from Spinal Cord, Percutaneous Endoscopic Approach

  • Billable / Specific Code
ICD-10-PCS 00PV4JZ
CMS Source: FY 2026 ICD-10-PCS dataset. Effective Oct 1, 2025 – Sep 30, 2026.FacebookXLinkedInPrint

00PV4JZ is a billable ICD-10-PCS procedure code for Removal of Synthetic Substitute from Spinal Cord, Percutaneous Endoscopic Approach. It is valid on HIPAA claims for fiscal year 2026 (October 1, 2025 through September 30, 2026) and groups to 18 MS-DRGs. The root operation Removal involves taking out or off a device from a body part.

Code Identity

ICD-10-PCS Code
00PV4JZ
Billable Status
Yes — Valid for Submission
Code Describes
Removal of Synthetic Substitute from Spinal Cord, Percutaneous Endoscopic Approach
Parent Code
Short Description
Removal of Synth Sub from Spinal Cord, Perc Endo Approach

PCS Table Breakdown

Each ICD-10-PCS code is built from seven characters, each an axis of the procedure. Hover or tap the icons for the official CMS definitions.

PositionDesignationValueMeaning
1Section0Medical and Surgical
2Body System0Central Nervous System and Cranial Nerves
3OperationPRemoval
4BodyPartVSpinal Cord
5Approach4Percutaneous Endoscopic
6DeviceJSynthetic Substitute
7QualifierZNo Qualifier

Convert to ICD-9-PCS

Closest ICD-9-PCS equivalents for 00PV4JZ under the General Equivalence Mappings.

32.9
Approximate match.

Similar Procedure Codes

Questions About 00PV4JZ

Is 00PV4JZ a billable code?

Yes. 00PV4JZ is a complete seven-character ICD-10-PCS code, specific enough to report Removal of Synthetic Substitute from Spinal Cord, Percutaneous Endoscopic Approach on inpatient claims from October 1, 2025 through September 30, 2026.

What do the characters in 00PV4JZ mean?

00PV4JZ breaks down character by character: the 1st character 0 is the Section (Medical and Surgical); the 2nd character 0 is the Body System (Central Nervous System and Cranial Nerves); the 3rd character P is the Operation (Removal); the 4th character V is the BodyPart (Spinal Cord); the 5th character 4 is the Approach (Percutaneous Endoscopic); the 6th character J is the Device (Synthetic Substitute); the 7th character Z is the Qualifier (No Qualifier).

What MS-DRG does 00PV4JZ group to?

On an inpatient stay, Removal of Synthetic Substitute from Spinal Cord, Percutaneous Endoscopic Approach maps to MS-DRGs 028, 029, 030, 423, 424, 425, 820, 821, 822, 826, 827, 828, 907, 908, 909, 957, 958, 959, with relative weights from 1.2040 to 7.6199. The MS-DRG sets the fixed Medicare payment for the stay.

What is the ICD-9-PCS equivalent of 00PV4JZ?

Under the General Equivalence Mappings, Removal of Synthetic Substitute from Spinal Cord, Percutaneous Endoscopic Approach crosswalks to ICD-9-PCS 32.9. The mapping is approximate, so confirm it fits the documentation.