MS-DRG 275 – Cardiac Defibrillator Implant with Cardiac Catheterization and MCC
A Surgical DRG in MDC 05 (Diseases & Disorders of the Circulatory System). Inpatient cases group to DRG 275 when one of the 104 ICD-10-PCS operating-room procedures listed below is reported. Its FY 2027 relative weight is 7.1571 with a geometric mean length of stay of 8.2 days.
The grouper first assigns the case to MDC 05 from the principal diagnosis, then matches a qualifying operating-room procedure from the ICD-10-PCS list below (this is a Surgical DRG).
Procedure Codes 104 codes · 29 categories
02H6 Heart and Great Vessels, Insertion6 codes
- 02H60KZ Insertion of Defibrillator Lead into Right Atrium, Open Approach
- 02H60MZ Insertion of Cardiac Lead into Right Atrium, Open Approach
- 02H63KZ Insertion of Defibrillator Lead into Right Atrium, Percutaneous Approach
- 02H63MZ Insertion of Cardiac Lead into Right Atrium, Percutaneous Approach
- 02H64KZ Insertion of Defibrillator Lead into Right Atrium, Percutaneous Endoscopic Approach
- 02H64MZ Insertion of Cardiac Lead into Right Atrium, Percutaneous Endoscopic Approach
02H7 Heart and Great Vessels, Insertion3 codes
02HK Heart and Great Vessels, Insertion6 codes
- 02HK0KZ Insertion of Defibrillator Lead into Right Ventricle, Open Approach
- 02HK0MZ Insertion of Cardiac Lead into Right Ventricle, Open Approach
- 02HK3KZ Insertion of Defibrillator Lead into Right Ventricle, Percutaneous Approach
- 02HK3MZ Insertion of Cardiac Lead into Right Ventricle, Percutaneous Approach
- 02HK4KZ Insertion of Defibrillator Lead into Right Ventricle, Percutaneous Endoscopic Approach
- 02HK4MZ Insertion of Cardiac Lead into Right Ventricle, Percutaneous Endoscopic Approach
02HL Heart and Great Vessels, Insertion3 codes
0JH6 Subcutaneous Tissue and Fascia, Insertion6 codes
- 0JH608Z Insertion of Defibrillator Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
- 0JH609Z Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
- 0JH60FZ Insertion of Subcutaneous Defibrillator Lead into Chest Subcutaneous Tissue and Fascia, Open Approach
- 0JH638Z Insertion of Defibrillator Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
- 0JH639Z Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
- 0JH63FZ Insertion of Subcutaneous Defibrillator Lead into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
0JH8 Subcutaneous Tissue and Fascia, Insertion4 codes
- 0JH808Z Insertion of Defibrillator Generator into Abdomen Subcutaneous Tissue and Fascia, Open Approach
- 0JH809Z Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Abdomen Subcutaneous Tissue and Fascia, Open Approach
- 0JH838Z Insertion of Defibrillator Generator into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach
- 0JH839Z Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Abdomen Subcutaneous Tissue and Fascia, Percutaneous Approach
0WHC Anatomical Regions, General, Insertion3 codes
4A02 Measurement and Monitoring, Physiological Systems, Measurement12 codes
- 4A020N6 Measurement of Cardiac Sampling and Pressure, Right Heart, Open Approach
- 4A020N7 Measurement of Cardiac Sampling and Pressure, Left Heart, Open Approach
- 4A020N8 Measurement of Cardiac Sampling and Pressure, Bilateral, Open Approach
- 4A023N6 Measurement of Cardiac Sampling and Pressure, Right Heart, Percutaneous Approach
- 4A023N7 Measurement of Cardiac Sampling and Pressure, Left Heart, Percutaneous Approach
- 4A023N8 Measurement of Cardiac Sampling and Pressure, Bilateral, Percutaneous Approach
- 4A027N6 Measurement of Cardiac Sampling and Pressure, Right Heart, Via Natural or Artificial Opening
- 4A027N7 Measurement of Cardiac Sampling and Pressure, Left Heart, Via Natural or Artificial Opening
- 4A027N8 Measurement of Cardiac Sampling and Pressure, Bilateral, Via Natural or Artificial Opening
- 4A028N6 Measurement of Cardiac Sampling and Pressure, Right Heart, Via Natural or Artificial Opening Endoscopic
- 4A028N7 Measurement of Cardiac Sampling and Pressure, Left Heart, Via Natural or Artificial Opening Endoscopic
- 4A028N8 Measurement of Cardiac Sampling and Pressure, Bilateral, Via Natural or Artificial Opening Endoscopic
B200 Imaging, Heart, Plain Radiography3 codes
B201 Imaging, Heart, Plain Radiography3 codes
B202 Imaging, Heart, Plain Radiography3 codes
B203 Imaging, Heart, Plain Radiography3 codes
B204 Imaging, Heart, Plain Radiography3 codes
B205 Imaging, Heart, Plain Radiography3 codes
B206 Imaging, Heart, Plain Radiography3 codes
B207 Imaging, Heart, Plain Radiography3 codes
B208 Imaging, Heart, Plain Radiography3 codes
B20F Imaging, Heart, Plain Radiography3 codes
B210 Imaging, Heart, Fluoroscopy3 codes
B211 Imaging, Heart, Fluoroscopy3 codes
B212 Imaging, Heart, Fluoroscopy3 codes
B213 Imaging, Heart, Fluoroscopy3 codes
B214 Imaging, Heart, Fluoroscopy3 codes
B215 Imaging, Heart, Fluoroscopy3 codes
B216 Imaging, Heart, Fluoroscopy3 codes
B217 Imaging, Heart, Fluoroscopy3 codes
B218 Imaging, Heart, Fluoroscopy3 codes
B21F Imaging, Heart, Fluoroscopy3 codes
XHH8 New Technology, Skin, Subcutaneous Tissue, Fascia and Breast, Insertion1 code
- XHH80JC Insertion of Contractility Modulation Device with Defibrillator Generator into Chest Subcutaneous Tissue and Fascia, Open Approach, New Technology Group 12
Qualifying Diagnosis Codes
Frequently Asked Questions
What is MS-DRG 275?
MS-DRG 275 (Cardiac Defibrillator Implant with Cardiac Catheterization and MCC) is a surgical DRG in MDC 05 (Diseases & Disorders of the Circulatory System). Its FY 2027 relative weight is 7.1571 with a geometric mean length of stay of 8.2 days.
How many procedure codes group to DRG 275?
104 ICD-10-PCS operating-room procedure codes group to this DRG.
What is the relative weight of DRG 275?
The FY 2027 relative weight of this DRG is 7.1571, meaning reimbursement of roughly 7.16 times the average Medicare inpatient case. Multiply by a hospital's blended base rate for the approximate payment.