ICD-10-PCS F13 Physical Rehabilitation and Diagnostic Audiology: Diagnostic Audiology Hearing Assessment

The ICD-10-PCS root operation Hearing Assessment (code F13) refers to the evaluation of hearing function using various diagnostic methods. Classified under Physical Rehabilitation and Diagnostic Audiology, this operation is focused on identifying hearing capabilities or impairments without invasive procedures.

This root operation covers a broad spectrum of hearing tests and screenings performed with specialized equipment. Examples include Hearing Screening Assessments using occupational hearing equipment (F13Z00Z), audiometers (F13Z01Z), tympanometers (F13Z03Z), or cochlear implant equipment (F13Z09Z). More detailed assessments include Pure Tone Audiometry for air and bone conduction (F13Z21Z), Bekesy Audiometry (F13Z31Z), Conditioned Play Audiometry (F13Z41Z), and Auditory Evoked Potentials assessments (F13ZL7Z). These codes also reflect different approaches employing sound booths, audiovisual devices, or computer assistance, reflecting the diverse tools used clinically to accurately document auditory function. Proper coding of these procedures supports comprehensive hearing evaluation and rehabilitation planning.

List of ICD-10-PCS codes used to specify F13 - Hearing Assessment (measurement of hearing and related functions). There are a total of 80 procedure codes in this section.

  • F13 - Physical Rehabilitation and Diagnostic Audiology, Diagnostic Audiology, Hearing Assessment

  • F13Z00Z - Hearing Screening Assessment using Occupational Hearing Equipment

  • F13Z01Z - Hearing Screening Assessment using Audiometer

  • F13Z02Z - Hearing Screening Assessment using Sound Field / Booth

  • F13Z03Z - Hearing Screening Assessment using Tympanometer

  • F13Z08Z - Hearing Screening Assessment using Vestibular / Balance Equipment

  • F13Z09Z - Hearing Screening Assessment using Cochlear Implant Equipment

  • F13Z0ZZ - Hearing Screening Assessment

  • F13Z10Z - Pure Tone Audiometry, Air Assessment using Occupational Hearing Equipment

  • F13Z11Z - Pure Tone Audiometry, Air Assessment using Audiometer

  • F13Z12Z - Pure Tone Audiometry, Air Assessment using Sound Field / Booth

  • F13Z1ZZ - Pure Tone Audiometry, Air Assessment

  • F13Z20Z - Pure Tone Audiometry, Air and Bone Assessment using Occupational Hearing Equipment

  • F13Z21Z - Pure Tone Audiometry, Air and Bone Assessment using Audiometer

  • F13Z22Z - Pure Tone Audiometry, Air and Bone Assessment using Sound Field / Booth

  • F13Z2ZZ - Pure Tone Audiometry, Air and Bone Assessment

  • F13Z31Z - Bekesy Audiometry Assessment using Audiometer

  • F13Z32Z - Bekesy Audiometry Assessment using Sound Field / Booth

  • F13Z3ZZ - Bekesy Audiometry Assessment

  • F13Z41Z - Conditioned Play Audiometry Assessment using Audiometer

  • F13Z42Z - Conditioned Play Audiometry Assessment using Sound Field / Booth

  • F13Z4KZ - Conditioned Play Audiometry Assessment using Audiovisual Equipment

  • F13Z4ZZ - Conditioned Play Audiometry Assessment

  • F13Z51Z - Select Picture Audiometry Assessment using Audiometer

  • F13Z52Z - Select Picture Audiometry Assessment using Sound Field / Booth

  • F13Z5KZ - Select Picture Audiometry Assessment using Audiovisual Equipment

  • F13Z5ZZ - Select Picture Audiometry Assessment

  • F13Z61Z - Visual Reinforcement Audiometry Assessment using Audiometer

  • F13Z62Z - Visual Reinforcement Audiometry Assessment using Sound Field / Booth

  • F13Z6ZZ - Visual Reinforcement Audiometry Assessment

  • F13Z71Z - Alternate Binaural or Monaural Loudness Balance Assessment using Audiometer

  • F13Z7KZ - Alternate Binaural or Monaural Loudness Balance Assessment using Audiovisual Equipment

  • F13Z7ZZ - Alternate Binaural or Monaural Loudness Balance Assessment

  • F13Z83Z - Tone Decay Assessment using Tympanometer

  • F13Z84Z - Tone Decay Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment

  • F13Z8ZZ - Tone Decay Assessment

  • F13Z91Z - Short Increment Sensitivity Index Assessment using Audiometer

  • F13Z92Z - Short Increment Sensitivity Index Assessment using Sound Field / Booth

  • F13Z9ZZ - Short Increment Sensitivity Index Assessment

  • F13ZB1Z - Stenger Assessment using Audiometer

  • F13ZB2Z - Stenger Assessment using Sound Field / Booth

  • F13ZBZZ - Stenger Assessment

  • F13ZC1Z - Pure Tone Stenger Assessment using Audiometer

  • F13ZC2Z - Pure Tone Stenger Assessment using Sound Field / Booth

  • F13ZCZZ - Pure Tone Stenger Assessment

  • F13ZD3Z - Tympanometry Assessment using Tympanometer

  • F13ZD4Z - Tympanometry Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment

  • F13ZDZZ - Tympanometry Assessment

  • F13ZF3Z - Eustachian Tube Function Assessment using Tympanometer

  • F13ZF4Z - Eustachian Tube Function Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment

  • F13ZFZZ - Eustachian Tube Function Assessment

  • F13ZG3Z - Acoustic Reflex Patterns Assessment using Tympanometer

  • F13ZG4Z - Acoustic Reflex Patterns Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment

  • F13ZGZZ - Acoustic Reflex Patterns Assessment

  • F13ZH3Z - Acoustic Reflex Threshold Assessment using Tympanometer

  • F13ZH4Z - Acoustic Reflex Threshold Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment

  • F13ZHZZ - Acoustic Reflex Threshold Assessment

  • F13ZJ3Z - Acoustic Reflex Decay Assessment using Tympanometer

  • F13ZJ4Z - Acoustic Reflex Decay Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment

  • F13ZJZZ - Acoustic Reflex Decay Assessment

  • F13ZK7Z - Electrocochleography Assessment using Electrophysiologic Equipment

  • F13ZKZZ - Electrocochleography Assessment

  • F13ZL7Z - Auditory Evoked Potentials Assessment using Electrophysiologic Equipment

  • F13ZLZZ - Auditory Evoked Potentials Assessment

  • F13ZM6Z - Evoked Otoacoustic Emissions, Screening Assessment using Otoacoustic Emission (OAE) Equipment

  • F13ZMZZ - Evoked Otoacoustic Emissions, Screening Assessment

  • F13ZN6Z - Evoked Otoacoustic Emissions, Diagnostic Assessment using Otoacoustic Emission (OAE) Equipment

  • F13ZNZZ - Evoked Otoacoustic Emissions, Diagnostic Assessment

  • F13ZP1Z - Aural Rehabilitation Status Assessment using Audiometer

  • F13ZP2Z - Aural Rehabilitation Status Assessment using Sound Field / Booth

  • F13ZP4Z - Aural Rehabilitation Status Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment

  • F13ZP9Z - Aural Rehabilitation Status Assessment using Cochlear Implant Equipment

  • F13ZPKZ - Aural Rehabilitation Status Assessment using Audiovisual Equipment

  • F13ZPLZ - Aural Rehabilitation Status Assessment using Assistive Listening Equipment

  • F13ZPPZ - Aural Rehabilitation Status Assessment using Computer

  • F13ZPZZ - Aural Rehabilitation Status Assessment

  • F13ZQKZ - Auditory Processing Assessment using Audiovisual Equipment

  • F13ZQPZ - Auditory Processing Assessment using Computer

  • F13ZQYZ - Auditory Processing Assessment using Other Equipment

  • F13ZQZZ - Auditory Processing Assessment