ICD-10-PCS X2H New Technology: Cardiovascular System Insertion

The ICD-10-PCS root operation Insertion (code starting with X2H) in the New Technology section refers to putting in a device that monitors, assists, or replaces a body function without cutting out or taking out body parts. This operation is specifically applied to the Cardiovascular System using new technologies.

Examples of this Insertion operation include placing bioprosthetic valves into major veins such as the Inferior Vena Cava (X2H03R9) or Superior Vena Cava (X2H13R9) through a Percutaneous Approach, or into the Right or Left Femoral Veins by an Open Approach. It also covers the insertion of dual-chamber intracardiac pacemakers into the Right Atrium (X2H63V9) and Right Ventricle (X2HK3V9) via percutaneous methods. Additionally, conduits for short-term external heart assist systems are inserted into locations like the Right and Left Axillary Arteries and the Ascending Thoracic Aorta by open approaches (X2HL0F9, X2HM0F9, X2HX0F9). Understanding these detailed codes aids accurate procedural documentation for advanced cardiovascular device placement using new technology techniques.

List of ICD-10-PCS codes used to specify X2H - Insertion (putting in a nonbiological appliance that monitors, assists, performs, or prevents aphysiological function but does not physically take the place of a body part). There are a total of 10 procedure codes in this section.

  • X2H - New Technology, Cardiovascular System, Insertion

  • X2H03R9 - Insertion of Intraluminal Device, Bioprosthetic Valve into Inferior Vena Cava, Percutaneous Approach, New Technology Gro...

  • X2H13R9 - Insertion of Intraluminal Device, Bioprosthetic Valve into Superior Vena Cava, Percutaneous Approach, New Technology Gro...

  • X2H20R9 - Insertion of Intraluminal Device, Bioprosthetic Valve into Right Femoral Vein, Open Approach, New Technology Group 9

  • X2H30R9 - Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9

  • X2H63V9 - Insertion of Dual-Chamber Intracardiac Pacemaker into Right Atrium, Percutaneous Approach, New Technology Group 9

  • X2HK3V9 - Insertion of Dual-Chamber Intracardiac Pacemaker into Right Ventricle, Percutaneous Approach, New Technology Group 9

  • X2HL0F9 - Insertion of Conduit to Short-term External Heart Assist System into Right Axillary Artery, Open Approach, New Technolog...

  • X2HM0F9 - Insertion of Conduit to Short-term External Heart Assist System into Left Axillary Artery, Open Approach, New Technology...

  • X2HX0F9 - Insertion of Conduit to Short-term External Heart Assist System into Thoracic Aorta, Ascending, Open Approach, New Techn...