2024 ICD-10-CM Diagnosis Code T82.111D

Breakdown (mechanical) of cardiac pulse generator (battery), subsequent encounter

ICD-10-CM Code:
T82.111D
ICD-10 Code for:
Breakdown of cardiac pulse generator (battery), subs
Is Billable?
Yes - Valid for Submission
Code Navigator:

Code Classification

  • Injury, poisoning and certain other consequences of external causes
    (S00–T88)
    • Complications of surgical and medical care, not elsewhere classified
      (T80-T88)
      • Complications of cardiac and vascular prosthetic devices, implants and grafts
        (T82)

T82.111D is a billable diagnosis code used to specify a medical diagnosis of breakdown (mechanical) of cardiac pulse generator (battery), subsequent encounter. The code is valid during the current fiscal year for the submission of HIPAA-covered transactions from October 01, 2023 through September 30, 2024. The code is exempt from present on admission (POA) reporting for inpatient admissions to general acute care hospitals.

T82.111D is a subsequent encounter code, includes a 7th character and should be used after the patient has completed active treatment for a condition like breakdown (mechanical) of cardiac pulse generator (battery). According to ICD-10-CM Guidelines a "subsequent encounter" occurs when the patient is receiving routine care for the condition during the healing or recovery phase of treatment. Subsequent diagnosis codes are appropriate during the recovery phase, no matter how many times the patient has seen the provider for this condition. If the provider needs to adjust the patient's care plan due to a setback or other complication, the encounter becomes active again.

Approximate Synonyms

The following clinical terms are approximate synonyms or lay terms that might be used to identify the correct diagnosis code:

  • Cardiac arrest due to pacemaker failure
  • Cardiac pacemaker battery malfunction
  • Disorder of pacemaker pulse generator
  • Failure of cardiac pacemaker to capture
  • Malfunction of biventricular cardiac pacemaker
  • Malfunction of biventricular cardiac pacemaker battery
  • Malfunction of cardiac pacemaker
  • Malfunction of cardiac pacemaker
  • Malfunction of cardiac pacemaker
  • Pacemaker battery depletion
  • Pacemaker pulse generator failure

Clinical Classification

Clinical Information

  • Failure of Cardiac Pacemaker to Capture

    failure to capture manifests as a high pacing threshold that results in either intermittent failure to capture at maximal programmed output or excessive battery drain leading to premature battery exhaustion.

Coding Guidelines

The appropriate 7th character is to be added to each code from block Complications of cardiac and vascular prosthetic devices, implants and grafts (T82). Use the following options for the aplicable episode of care:

  • A - initial encounter
  • D - subsequent encounter
  • S - sequela

Present on Admission (POA)

T82.111D is exempt from POA reporting - The Present on Admission (POA) indicator is used for diagnosis codes included in claims involving inpatient admissions to general acute care hospitals. POA indicators must be reported to CMS on each claim to facilitate the grouping of diagnoses codes into the proper Diagnostic Related Groups (DRG). CMS publishes a listing of specific diagnosis codes that are exempt from the POA reporting requirement. Review other POA exempt codes here.

CMS POA Indicator Options and Definitions

POA IndicatorReason for CodeCMS will pay the CC/MCC DRG?
YDiagnosis was present at time of inpatient admission.YES
NDiagnosis was not present at time of inpatient admission.NO
UDocumentation insufficient to determine if the condition was present at the time of inpatient admission.NO
WClinically undetermined - unable to clinically determine whether the condition was present at the time of inpatient admission.YES
1Unreported/Not used - Exempt from POA reporting. NO

Convert T82.111D to ICD-9-CM

  • ICD-9-CM Code: V58.89 - Other specfied aftercare
    Approximate Flag - The approximate mapping means there is not an exact match between the ICD-10 and ICD-9 codes and the mapped code is not a precise representation of the original code.

Patient Education


Pacemakers and Implantable Defibrillators

An arrhythmia is any disorder of your heart rate or rhythm. It means that your heart beats too quickly, too slowly, or with an irregular pattern. Most arrhythmias result from problems in the electrical system of the heart. If your arrhythmia is serious, you may need a cardiac pacemaker or an implantable cardioverter defibrillator (ICD). They are devices that are implanted in your chest or abdomen.

A pacemaker helps control abnormal heart rhythms. It uses electrical pulses to prompt the heart to beat at a normal rate. It can speed up a slow heart rhythm, control a fast heart rhythm, and coordinate the chambers of the heart.

An ICD monitors heart rhythms. If it senses dangerous rhythms, it delivers shocks. This treatment is called defibrillation. An ICD can help control life-threatening arrhythmias, especially those that can cause sudden cardiac arrest (SCA). Most new ICDs can act as both a pacemaker and a defibrillator. Many ICDs also record the heart's electrical patterns when there is an abnormal heartbeat. This can help the doctor plan future treatment.

Getting a pacemaker or ICD requires minor surgery. You usually need to stay in the hospital for a day or two, so your doctor can make sure that the device is working well. You will probably be back to your normal activities within a few days.


[Learn More in MedlinePlus]

Code History

  • FY 2024 - No Change, effective from 10/1/2023 through 9/30/2024
  • FY 2023 - No Change, effective from 10/1/2022 through 9/30/2023
  • FY 2022 - No Change, effective from 10/1/2021 through 9/30/2022
  • FY 2021 - No Change, effective from 10/1/2020 through 9/30/2021
  • FY 2020 - No Change, effective from 10/1/2019 through 9/30/2020
  • FY 2019 - No Change, effective from 10/1/2018 through 9/30/2019
  • FY 2018 - No Change, effective from 10/1/2017 through 9/30/2018
  • FY 2017 - No Change, effective from 10/1/2016 through 9/30/2017
  • FY 2016 - New Code, effective from 10/1/2015 through 9/30/2016. This was the first year ICD-10-CM was implemented into the HIPAA code set.